Explore companies/Anton Paar

Company details

Anton Paar supplies laboratory particle characterization instruments for powders and liquid dispersions. The Litesizer range includes dynamic light scattering, laser diffraction and dynamic image analysis. The Graz headquarters is the Austrian manufacturer and instrument enquiry point.

Capabilities
Equipment & Instruments
Locations covered

Registered company

Legal name
Anton Paar GmbH
Country of registration
Austria · European Union
Registration number
FN 135863 z
Registered office
Anton-Paar-Straße 20, 8054 Graz, Styria, Austria
Legal details on company website

Anton Paar Graz Headquarters

Anton-Paar-Straße 20, 8054 Graz, Styria, Austria · EU site

Contacts & support

Anton Paar headquarters enquiries
email contact | +43 316 257 0Source · Checked

Products & services

21 listed for Graz, Austria

Kalliope Particle Analysis Software

Anton Paar · Graz, Austria

Software interface for setting up methods, monitoring particle measurements and evaluating results across Litesizer instruments.

Selection notes
Choose by installed instruments and required audit trail and electronic record features.
What to ask
Which software licence, validation options and upgrades are included?

Litesizer Autosampler for DIF and DIA

Anton Paar · Graz, Austria

Supports automated handling of dry and wet samples for Litesizer DIF and DIA analyzers. The vendor lists up to 60 samples per run.

Selection notes
Select by delivery workflow, dispersion unit and model compatibility.
What to ask
What sample size, vessel format and system footprint are needed?

Litesizer Cuvette Sampler

Anton Paar · Graz, Austria

Automates loading for compatible DLS workflows, with up to 80 cuvettes in a sequence.

Selection notes
Select by DLS model, measurement modes and compatible disposable, glass, quartz or Omega cuvettes.
What to ask
Which sample holders and software options are included and qualified?

Litesizer DIA 100

Anton Paar · Graz, Austria

Dynamic image analyzer with 1 magnification setting. The published lower Liquid Flow limit is 10 µm.

Selection notes
Select for joint size and shape measurements. Confirm the working range with the Liquid Flow, Small Flow, Dry Jet or Free Fall unit.
What to ask
Which dispersion unit and image analysis parameters suit our powders or granules?

Litesizer DIA 500

Anton Paar · Graz, Austria

Dynamic image analyzer with 2 magnification settings. The published lower Liquid Flow limit is 0.8 µm.

Selection notes
Select for joint size and shape measurements. Confirm the working range with the Liquid Flow, Small Flow, Dry Jet or Free Fall unit.
What to ask
Which dispersion unit and image analysis parameters suit our powders or granules?

Litesizer DIA 700

Anton Paar · Graz, Austria

Dynamic image analyzer with 3 magnification settings. The published lower Liquid Flow limit is 0.5 µm.

Selection notes
Select for joint size and shape measurements. Confirm the working range with the Liquid Flow, Small Flow, Dry Jet or Free Fall unit.
What to ask
Which dispersion unit and image analysis parameters suit our powders or granules?

Litesizer DIF 100

Anton Paar · Graz, Austria

Laser diffraction particle size analyzer with a manufacturer-stated measurement range of 0.1–1,000 µm.

Selection notes
Select by expected distribution and whether dry powder or wet dispersion handling is needed. Confirm whether the chosen optional module is compatible with DIF 100.
What to ask
Which dispersion unit and standards can be included for our pharmaceutical samples?

Litesizer DIF 300

Anton Paar · Graz, Austria

Laser diffraction particle size analyzer with a manufacturer-stated measurement range of 0.1–2,500 µm.

Selection notes
Select by expected distribution and whether dry powder or wet dispersion handling is needed. Confirm whether the chosen optional module is compatible with DIF 300.
What to ask
Which dispersion unit and standards can be included for our pharmaceutical samples?

Litesizer DIF 500

Anton Paar · Graz, Austria

Laser diffraction particle size analyzer with a manufacturer-stated measurement range of 0.01–3,500 µm.

Selection notes
Select by expected distribution and whether dry powder or wet dispersion handling is needed. Confirm whether the chosen optional module is compatible with DIF 500.
What to ask
Which dispersion unit and standards can be included for our pharmaceutical samples?

Litesizer DLS 101

Anton Paar · Graz, Austria

Single-angle DLS analyzer for particle sizing in conventional liquid dispersions, with 175° backscatter detection.

Selection notes
Choose for routine particle sizing in a single backscatter geometry.
What to ask
Which cuvettes and validated sample volume suit the intended suspension?

Litesizer DLS 301

Anton Paar · Graz, Austria

Single-angle DLS instrument using 90° scattering for particle sizing.

Selection notes
Select where a side-scatter model is appropriate. Compare practical sample volume and concentration limits.
What to ask
Can the supplier demonstrate the detection geometry using representative samples?

Litesizer DLS 501

Anton Paar · Graz, Austria

Three-angle DLS instrument that also offers zeta potential and selected additional analytical modes.

Selection notes
Choose for work comparing particle size and dispersion properties across formulations.
What to ask
Which zeta potential cuvettes, calibration records and software are included?

Litesizer DLS 701

Anton Paar · Graz, Austria

Multi-angle DLS analyzer with zeta potential and a dedicated particle concentration mode.

Selection notes
Select for sample-dependent count measurements and multi-angle size analysis as well as routine DLS.
What to ask
Which concentration range, cuvettes and accuracy apply to the proposed sample?

Litesizer Dry Jet Dispersion Unit

Anton Paar · Graz, Austria

Compressed-air dry dispersion for compatible Litesizer particle analyzers.

Selection notes
Select for appropriate dry powders requiring pneumatic dispersion.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Free Fall Dispersion Unit

Anton Paar · Graz, Austria

Gravity-fed dry handling module for compatible Litesizer DIA analyzers.

Selection notes
Choose for coarse, fragile or weakly agglomerated samples where gentle dispersion is needed.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Liquid Flow Chemical Dispersion Unit

Anton Paar · Graz, Austria

Wet dispersion module designed with increased resistance to aggressive media.

Selection notes
Select when the standard wet dispersion module's materials are unsuitable.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Liquid Flow Dispersion Unit

Anton Paar · Graz, Austria

Liquid carrier module for wet measurement with compatible DIA and DIF systems.

Selection notes
Select for ordinary wet dispersions where a recirculating liquid module is appropriate.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Liquid Flow Imaging Chemical Dispersion Unit

Anton Paar · Graz, Austria

Chemically resistant imaging dispersion module for eligible wet laser diffraction applications.

Selection notes
Select when particle shape information and increased material resistance are both required.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Liquid Flow Imaging Dispersion Unit

Anton Paar · Graz, Austria

Adds image-based particle shape information to suitable wet laser diffraction measurements.

Selection notes
Select for compatible DIF 300 or 500 workflows that need both size and shape information.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Small Flow Dispersion Unit

Anton Paar · Graz, Austria

Low-volume wet dispersion module for samples where the liquid or sample quantity is limited.

Selection notes
Select for limited sample or liquid supply. Confirm solvent and material compatibility.
What to ask
Which analyzer models, media and parts are supported by this module?

Litesizer Small Flow Imaging Dispersion Unit

Anton Paar · Graz, Austria

Reduced-volume liquid dispersion with integrated dynamic imaging for compatible DIF instruments.

Selection notes
Select when sample volume is limited and both diffraction and imaging are required.
What to ask
Which analyzer models, media and parts are supported by this module?