BT-A60 particle size analysis autosampler
Bettersize Instruments · Dandong, China
Automated sample handling module for supported Bettersizer workflows.
- Selection notes
- The manufacturer lists up to 60 queued samples and compatibility with the Bettersizer 2600 and S3 Plus.
- What to ask
- Which sample vessels, dispersion modules and software versions are compatible?
BT-Online1 dry process particle size analyzer
Bettersize Instruments · Dandong, China
Online system for continuous monitoring of dry particle streams.
- Selection notes
- Selection depends on a representative dry-process sampling interface and line integration.
- What to ask
- Which sampler and interface are required to track our dry milling or granulation stream?
BT-Online2 wet process particle size analyzer
Bettersize Instruments · Dandong, China
Online analyzer for particle sizing in a wet process stream.
- Selection notes
- Uses a dual-tank arrangement with automated dispersant dosing and ultrasonic dispersion for compatible samples.
- What to ask
- Can the wet sampling and cleaning arrangement handle the expected solids concentration?
BeNano 180 Pro nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions.
- Selection notes
- The model matrix lists 90° and 173° sizing, a sample-dependent range of 0.3 nm–15 µm and minimum size-test volume of 3 µL with a suitable cell.
- What to ask
- Can both scattering angles be demonstrated on the same formulation samples?
BeNano 180 Zeta Max nanoparticle analyzer
Bettersize Instruments · Dandong, China
Characterizes colloidal particle size, zeta potential and concentration on a multi-parameter platform.
- Selection notes
- The pharmaceutical particle analyzer index lists 0.3 nm–15 µm. Select the cell and configuration for the required measurements.
- What to ask
- Which particle concentration and zeta potential modes can be demonstrated on our suspension?
BeNano 180 Zeta Pro nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions with electrophoretic zeta potential measurement.
- Selection notes
- The model matrix lists 90° and 173° sizing, a sample-dependent range of 0.3 nm–15 µm and minimum size-test volume of 3 µL with a suitable cell.
- What to ask
- Can the quote include the required sizing and electrophoretic measurement cells?
BeNano 180 Zeta nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions with electrophoretic zeta potential measurement.
- Selection notes
- The model matrix lists 173° sizing, a sample-dependent range of 0.3 nm–10 µm and minimum size-test volume of 40 µL with a suitable cell.
- What to ask
- Which zeta cell and backscatter sample cell match the formulation conductivity and volume?
BeNano 180 nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions.
- Selection notes
- The model matrix lists 173° sizing, a sample-dependent range of 0.3 nm–10 µm and minimum size-test volume of 40 µL with a suitable cell.
- What to ask
- What dispersion concentrations and cell types suit the backscatter sizing configuration?
BeNano 90 Zeta nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions with electrophoretic zeta potential measurement.
- Selection notes
- The model matrix lists 90° sizing, a sample-dependent range of 0.3 nm–15 µm and minimum size-test volume of 3 µL with a suitable cell.
- What to ask
- Which size and zeta cells support our available sample volume?
BeNano 90 nanoparticle analyzer
Bettersize Instruments · Dandong, China
Light scattering analyzer for particle sizing in dispersions.
- Selection notes
- The model matrix lists 90° sizing, a sample-dependent range of 0.3 nm–15 µm and minimum size-test volume of 3 µL with a suitable cell.
- What to ask
- Which low-volume cell is suitable for a clear trial dispersion?
BeVision D3 dynamic image analyzer
Bettersize Instruments · Dandong, China
Automatically measures particle size and shape as particles move through the imaging field.
- Selection notes
- The family range is 0.5 µm–26 mm across optical and dispersion configurations. Compare fine and macro setups for the intended sample.
- What to ask
- Which optical configuration and wet or dry presentation cover the required particle range?
BeVision M1 automated static image analyzer
Bettersize Instruments · Dandong, China
Automated microscopy for particle size and shape in prepared samples.
- Selection notes
- The series lists 0.3–10,000 µm. Select sample preparation and optical settings for the required size and shape measures.
- What to ask
- Which magnifications and stage coverage are appropriate for the sample population?
BeVision S1 static image analyzer
Bettersize Instruments · Dandong, China
Static imaging system for size and shape analysis of wet or dry particle preparations.
- Selection notes
- The stated measurement range is 0.3–4,500 µm across supported configurations.
- What to ask
- Which sample holder and magnification cover suspensions and dry particles in the same laboratory?
Bettersizer 2600 Plus particle size and shape analyzer
Bettersize Instruments · Dandong, China
Modular laser diffraction analyzer with optional dual-camera image analysis.
- Selection notes
- Published laser ranges are 0.02–2,600 µm wet and 0.1–2,600 µm dry. Optional imaging covers 2–3,500 µm under documented conditions.
- What to ask
- Which wet unit and imaging module are required to measure both distribution and shape?
Bettersizer 2600 laser diffraction particle size analyzer
Bettersize Instruments · Dandong, China
Modular laser diffraction system for laboratory measurement of pharmaceutical powders and dispersions.
- Selection notes
- Published size ranges are 0.02–2,600 µm wet and 0.1–2,600 µm dry.
- What to ask
- Which dispersion unit and sample feeder suit the expected material and size range?
Bettersizer S3 Plus particle size and shape analyzer
Bettersize Instruments · Dandong, China
Combines laser diffraction and dynamic imaging in a laboratory instrument.
- Selection notes
- The supplier states 0.01–3,500 µm for laser sizing and 2–3,500 µm for imaging.
- What to ask
- Can a demonstration compare laser sizing with image results for coarse particles or agglomerates?
Bettersizer ST wet particle size analyzer
Bettersize Instruments · Dandong, China
Compact wet-dispersion laser diffraction instrument for routine quality control.
- Selection notes
- The family page lists a size range of 0.1–1,000 µm. The dispersion workflow is wet.
- What to ask
- What sample loading, cleaning and reporting workflows are included for routine tests?