Hydro Insight dynamic imaging accessory
Malvern Panalytical · Malvern, United Kingdom
Adds flow-through particle imaging and shape analysis to a compatible Mastersizer wet setup.
- Selection notes
- Provides quantitative shape data from the same wet dispersion used for laser diffraction.
- What to ask
- Which Mastersizer and Hydro dispersion configuration supports the proposed imaging workflow?
Insitec Dry particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
At-line or online laser diffraction for flowing dry powders and granules.
- Selection notes
- The published 0.1–2,500 µm range covers a dry pneumatic or gravity-fed stream with the engineered interface.
- What to ask
- Which sampler, air handling and product-path qualification are included?
Insitec Spray particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Laser diffraction process analyzer for monitoring droplets and dry particles in sprays.
- Selection notes
- Size range 0.1–2,500 µm. The product profile explicitly includes spray drying process monitoring.
- What to ask
- How is optical access and measurement representativeness verified at the proposed spray point?
Insitec Wet particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
At-line or online laser diffraction for suspensions, emulsions and slurries.
- Selection notes
- Published sizing range is 0.1–2,500 µm with an application-specific plant interface.
- What to ask
- Which sample loop, dilution and cleaning provisions suit our wet process stream?
Malvern applications laboratory particle-sizing feasibility
Malvern Panalytical · Malvern, United Kingdom
Customer sample evaluation to compare instrument and measurement options before purchase.
- Selection notes
- The manufacturer identifies an applications lab at its UK divisional headquarters and describes using customer samples and methods.
- What to ask
- Can the UK lab test our sample and return repeatability and method selection data for the quoted instruments?
Mastersizer 3000+ Lab particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Entry-level laser diffraction model with basic Xplorer software and an upgrade path to Pro or Ultra.
- Selection notes
- The published particle size range is 0.1–1,000 µm. Confirm it against the requested dispersion and material.
- What to ask
- Which dispersion choices and compliant workflow software are included in the Lab configuration?
Mastersizer 3000+ Pro particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Laser diffraction unit for micron-scale work with six stated wet dispersion accessories and an Ultra upgrade path.
- Selection notes
- The published particle size range is 0.1–2,500 µm. Confirm it against the requested dispersion and material.
- What to ask
- Which accessory suits our sample mass, solvent compatibility and expected coarse tail?
Mastersizer 3000+ Ultra particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Widest listed range with a selection of six wet-dispersion accessories and a dry-dispersion option.
- Selection notes
- The published particle size range is 0.01–3,500 µm. Confirm it against the requested dispersion and material.
- What to ask
- Which wet or dry unit and software features are quoted for our full particle size range?
Mastersizer Auto-Lab autosampler
Malvern Panalytical · Malvern, United Kingdom
Enclosed sample handling system for automated laser diffraction workflows.
- Selection notes
- The model page lists capacity for up to 42 samples on the specified Mastersizer 3000 configuration.
- What to ask
- Which current Mastersizer variants and dispersion methods are compatible with this sample queue?
Morphologi 4 particle analyzer
Malvern Panalytical · Malvern, United Kingdom
Automated static image analyzer for particle size, shape and count.
- Selection notes
- The published nominal range is 0.5–1,300 µm, depending on sample and substrate. Dry powder dispersion is integrated.
- What to ask
- Which lens and sample preparation accessories support our particles and size distribution?
Morphologi 4-ID particle analyzer
Malvern Panalytical · Malvern, United Kingdom
Automated particle imaging instrument with morphology-directed Raman identification.
- Selection notes
- The combination can differentiate components in a powder mixture where Raman spectra and particle preparation permit.
- What to ask
- Can the system distinguish the drug substance from our excipients and report component-specific size?
NanoSight Pro nanoparticle analyzer
Malvern Panalytical · Malvern, United Kingdom
Nanoparticle tracking analyzer for sizing and counting dispersed particles, including formulation research materials.
- Selection notes
- Supplier specification gives a sample-dependent diameter range of 10–1,000 nm and a minimum 250 µL volume.
- What to ask
- What sample dilution and verification are needed for the expected particle size and concentration?
Particle sizing method development consultancy
Malvern Panalytical · Malvern, United Kingdom
Application scientist support to develop a reproducible particle characterization method.
- Selection notes
- Malvern lists method development, sample preparation and result interpretation among its consultancy options. Confirm the UK base and agreed deliverables.
- What to ask
- Which method protocol, data and transfer support will be included, and which work is performed at the Malvern lab?
Spraytec spray droplet size analyzer
Malvern Panalytical · Malvern, United Kingdom
Laboratory laser diffraction instrument for time-resolved droplet size characterization.
- Selection notes
- Published family range is 0.1–2,000 µm across available optics. Select an optical arrangement for the expected droplet range.
- What to ask
- Which lens and spray test fixture are matched to our drug product presentation?
Zetasizer Lab particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Dynamic light scattering instrument with 90-degree detection, suitable for routine dispersed formulation samples.
- Selection notes
- The configured capillary cell and extended-range analysis can extend the upper sizing range to 15 µm. Blue and Red Label configurations are listed.
- What to ask
- Which configuration and cell meet our sample volume and upper size limit?
Zetasizer Pro particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Light-scattering platform with backscatter sizing and zeta potential measurement for dispersions.
- Selection notes
- The published size range is 0.3 nm to 10 µm. Blue and Red Label configurations and multiple sample presentation options are offered.
- What to ask
- Which label and flow or batch cell can support the anticipated sample range?
Zetasizer Ultra Blue Label particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Multi-angle light-scattering platform for higher-resolution sizing of pharmaceutical dispersions.
- Selection notes
- Blue Label is offered for routine samples. It includes the Ultra platform's multi-angle size analysis.
- What to ask
- Can the Blue Label configuration resolve the expected particle populations in our formulation?
Zetasizer Ultra Red Label particle size analyzer
Malvern Panalytical · Malvern, United Kingdom
Multi-angle light-scattering platform for higher-resolution sizing of pharmaceutical dispersions.
- Selection notes
- Red Label adds compatible particle concentration measurement, according to the product comparison.
- What to ask
- What particle concentration range, sample characteristics and cells apply to our formulation?